To check BIOS setting, boot into the BIOS menu and verify all the setting below:
BIOS Settings
- Intel ® Hyper-Threading Tech
- Enabled
- Intel ® Virtualization
- Enabled
- CPU Power and Performance Policy
- Performance
- Workload Configuration
- I/O Sensitive
- CPU P State Control
- Enhanced Intel SpeedStep ® Tech: Enabled
- Intel Configuration TDP: Disabled
- Intel ® Turbo Boost Technology: Enabled
- Energy Efficient Turbo: Disabled
- CPU C State Control
- Package C-State: No Limit
- C1E: Disabled
- Processor C6: Disabled
- System Acoustic and Performance Configuration
- Set Fan Profile: Performance
Please note that the look of the BIOS screen may look different depending on BIOS version. Note: The screenshot is for example of the location of the setting. Setting may be incorrect.
- Intel ® Hyper-Threading Tech and Intel ® Virtualization
Advanced > Processor Configuration
- CPU Power and Performance Policy and Workload Configuration
Advanced > Power & Performance
- CPU P State Control
Advanced > Power & Performance > CPU P State Control
- CPU C State Control
Advanced > Power & Performance > CPU C State Control
- System Acoustic and Performance Configuration
Advanced > System Acoustic and Performance Configuration
If your OS Raid is not set and you require to set the OS back to RAID. Go to:
- Advanced > Mass Storage Controller Configuration >sSATA Controller (Port 0- 5), Change AHCI Capable sSATA Controller to RAID MODE
BIOS Setting in BMC Web Console
Log into the BMC web console. Once log in, select the BIOS configurations tabs on the far right.
On the left is your configuration tab. Select the following tab to go to the setting to enable or disable the settings.
- Intel ® Hyper-Threading Tech and Intel ® Virtualization
BIOS Configurations > Processor Configuration
Use the first drop-down box to select Hyper-Threading Tech or Virtualization. Use the second drop-down box to Enable or Disable the configuration. Select save for each configuration setting change
- CPU Power and Performance Policy, Workload Configuration, CPU P State Control, and CPU C State Control
BIOS Configurations > Power n Performance
Use the first drop-down box to configuration setting you want to change. Use the second drop-down box to select the configuration
- Performance
- I/O Sensitive
- Enhanced Intel SpeedStep ® Tech: Enabled
- Intel Configuration TDP: Disabled
- Intel ® Turbo Boost Technology: Enabled
- Energy Efficient Turbo: Disabled
- Package C-State: No Limit
- C1E: Disabled
- Processor C6: Disabled
Select save for each configuration setting change
- System Acoustic and Performance Configuration
BIOS Configurations > System Acoustic and Performance Configuration
Select save for each configuration setting change
If your OS Raid is not set and you require to set the OS back to RAID. Go to:
- BIOS Configurations > Mass Storage Controller Configuration
- Use the drop box to select AHCI Capable sSATA Controller and use the second drop box to select RAID
Select save for each configuration setting change
www.dataonstorage.com | 1-888-725-8588 | [email protected]
Copyright © 2021 DataON. All Rights Reserved. Specifications may change without notice. DataON is not responsible for photographic or typographical errors. DataON, the DataON logo, MUST, and the MUST logo are trademarks of DataON in the United States and certain other countries. Other company, product, or services names may be trademarks or service marks of others.